Homeapotherapy research desk Find my starting point

Product fact sheet

Hooga ULTRA1500 Technical Profile

Hooga ULTRA1500 specifications list 300 LEDs, 630/660/810/850 nm output, adjustable pulse behavior, a 39.5-inch panel and separate 1500 W rated and 478.5 W output-power fields.

Red-light therapy guideReturn to the therapy guide and compare device specifications in context. Compare in context → Red-light panel comparisonOpen the comparison surface for this product family; missing comparable data is shown rather than guessed. Compare products →
Desk researchedFacts checked 2026-08-11

A taller 300-LED four-wavelength ULTRA panel with pulse controls and a 39.5-inch manual-listed height.

Fit signals

larger four-wavelength comparisons, buyers who value primary-manual control and hardware details

Potential constraints

buyers requiring independent common-protocol testing, anyone assuming more LEDs means better clinical results

Key tradeoff: The manual gives a broad hardware record; independent measurements remain the main evidence gap.

This is a factual fit-and-tradeoff summary, not a product recommendation. Formula, device and brand claims remain manufacturer claims unless the cited source is explicitly regulatory or independent testing.

Technical record

The 2025 ULTRA-series manual lists the ULTRA1500 at 39.5 × 8.6 × 2.5 inches, with 300 LEDs, 630 / 660 / 810 / 850 nm wavelength bands and a 60° beam angle. Adjustable pulse behavior is documented in the same manual.

The table gives 1500 W rated power and a separate 478.5 W output-power field. The manual’s labels should be preserved as written; neither field should be treated as a proxy for clinical effect or assumed to equal independently measured optical radiant power.

Evidence boundary

No compatible independent common-protocol optical result is available for this model in the current record. Setup, heat, noise, electrical draw and treatment-area uniformity have not been independently characterized here.

The four-wavelength set and adjustable pulse behavior are hardware features. Their presence does not establish that pulsing or a larger wavelength count improves outcomes for a specific condition.

Technical specifications

Published specs and what they mean

Physical

Dimensions
39.5 × 8.6 × 2.5 in
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

Optical

Wavelengths
630 / 660 / 810 / 850 nm
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)
LED quantity
300 LEDs
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)
Rated power
1500 W
Basis: Manufacturer manual Manufacturer rated-power label. Source: Hooga ULTRA Series User Manual (PDF)
Beam angle
60°
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

Electrical

Manual-listed output power
478.5 W
Basis: Manufacturer manual Preserves the manual's field wording; not treated as an independent measurement. Source: Hooga ULTRA Series User Manual (PDF)
Power input
AC 85–265 V
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

Controls

Pulse control
1–100 Hz adjustable; manufacturer presets described
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

What the current record does not establish

  • No independent common-protocol optical measurement is normalized.
  • Manufacturer irradiance/coverage charts are not treated as third-party verification.
  • No Homeapotherapy hands-on setup, fan-noise or heat measurements exist.

A missing field is not evidence that the device lacks the feature or performs poorly. It means we do not currently have a sufficiently comparable, sourced value in the normalized record.

Source labels preserve provenance. Manufacturer specifications, ingredient lists and performance claims are not treated as independent clinical evidence; regulatory records and independent measurements are identified separately when available.

Dose and irradiance context

What the output number means over time

Fluence is a calculation, not a treatment recommendation. For continuous output, fluence in J/cm² equals irradiance in mW/cm² × seconds ÷ 1000. The calculation only remains meaningful at the measurement conditions used for the irradiance value.

No comparable independent average irradiance is normalized

This device may have a manufacturer-published irradiance claim, but Homeapotherapy does not calculate time-to-fluence from that number unless the current record contains a sufficiently defined independent area-average measurement. This avoids presenting unlike measurement methods as interchangeable.

What this calculation still cannot tell you

  • whether this is an effective dose for any condition;
  • how irradiance changes at a different distance or across curved anatomy;
  • how much energy reaches tissue below the surface;
  • whether a study used the same wavelength distribution, spot size, pulse mode or treatment schedule;
  • whether peak irradiance would produce the same area exposure as the average value shown here.

Read Red Light Irradiance, Fluence and Dose Explained before trying to compare this output with a clinical paper or another panel.

Clinical evidence context

Where these wavelengths overlap with human research

Published device wavelengths: 630 / 660 / 810 / 850 nm.

This is a hardware-to-literature cross-reference, not a claim that this product treats any condition. A matching nominal wavelength does not reproduce a study's irradiance, dose, distance, treatment area, emitter geometry, schedule or patient population.

Research areas worth checking

Do not infer from wavelength overlap

  • that this device is clinically proven for the linked condition;
  • that more wavelengths are better;
  • that the highest published irradiance is the best dose;
  • that an open wound should be treated with a consumer device without appropriate wound assessment.

For wounds specifically, start with the wound-care safety decision guide before interpreting any device specification.

Safety first

What should make you slow down?

Use the current manufacturer manual for eye protection, electrical operation and pulse controls. Size, LED count and pulse options do not establish treatment superiority.

  • The manufacturer manual contains eye-exposure and electrical-safety warnings.
  • Manufacturer irradiance and coverage plots should not be presented as independent lab verification.

Where to buy

Current tracked merchants

Commerce note: merchant economics never enter our editorial score. Affiliate links are identified as (paid link) and use sponsored-link markup.

No merchant destination is currently tracked for this product.

Source trail

Primary documents and supporting evidence

  1. Hooga ULTRA Series User ManualHooga · Manufacturer manual · PDF · retrieved 2026-08-11
  2. Hooga Quality & Certifications: What We Can VerifyHooga · Manufacturer · retrieved 2026-08-10
  3. Photobiomodulation (PBM) Devices - Premarket Notification [510(k)] SubmissionsU.S. Food and Drug Administration · Regulatory · retrieved 2026-08-10