Homeapotherapy research desk Find my starting point

Product fact sheet

Hooga ULTRA750 Technical Profile

Hooga ULTRA750 specifications from the 2025 manufacturer manual, including dimensions, four wavelengths, 150 LEDs, beam angle, pulse controls and the limits of manufacturer-only output data.

Red-light therapy guideReturn to the therapy guide and compare device specifications in context. Compare in context → Red-light panel comparisonOpen the comparison surface for this product family; missing comparable data is shown rather than guessed. Compare products →
Desk researchedFacts checked 2026-08-11

A 150-LED four-wavelength ULTRA panel with adjustable pulse controls and a 20.4-inch manual-listed height.

Fit signals

mid-size four-wavelength comparisons, buyers wanting a current primary manual

Potential constraints

buyers requiring independent irradiance, buyers who want clinical ranking from hardware features

Key tradeoff: Detailed controls and hardware documentation, but no normalized independent optical test is in the record.

This is a factual fit-and-tradeoff summary, not a product recommendation. Formula, device and brand claims remain manufacturer claims unless the cited source is explicitly regulatory or independent testing.

Published hardware specifications

The 2025 ULTRA manual lists the ULTRA750 at 20.4 × 8.6 × 2.5 inches, with 150 LEDs, 630 / 660 / 810 / 850 nm output bands and a 60° beam angle. The manual also documents pulse controls and AC 85–265 V input.

These are manufacturer specifications. They describe the device configuration, not treatment effectiveness.

Rated power and output-power fields

The specification table gives 750 W rated power and a separate 248.2 W output-power field.

Those labels describe different quantities and should remain separate. Neither number should be converted into a clinical-performance score or compared with another manufacturer’s differently defined “power” figure without a common measurement method.

Independent measurement gap

No independent common-protocol irradiance result is normalized for this device in the current record. Wall draw, optical output, heat, noise and beam uniformity have not been measured by the publication under a shared cross-brand protocol.

That leaves the manual as the main source for hardware specifications. Manufacturer coverage or irradiance charts should be treated as manufacturer evidence unless independently reproduced.

For the difference between wavelength, irradiance, radiant power and electrical draw, see How to Read Red Light Device Specifications.

Technical specifications

Published specs and what they mean

Physical

Dimensions
20.4 × 8.6 × 2.5 in
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

Optical

Wavelengths
630 / 660 / 810 / 850 nm
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)
LED quantity
150 LEDs
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)
Rated power
750 W
Basis: Manufacturer manual Manufacturer rated-power label. Source: Hooga ULTRA Series User Manual (PDF)
Beam angle
60°
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

Electrical

Manual-listed output power
248.2 W
Basis: Manufacturer manual Preserves the manual's field wording; not treated as an independent measurement. Source: Hooga ULTRA Series User Manual (PDF)
Power input
AC 85–265 V
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

Controls

Pulse control
1–100 Hz adjustable; manufacturer presets described
Basis: Manufacturer manual 2025 ULTRA manual. Source: Hooga ULTRA Series User Manual (PDF)

What the current record does not establish

  • No independent common-protocol optical measurement is normalized.
  • Manufacturer irradiance/coverage charts remain manufacturer evidence.
  • No Homeapotherapy hands-on testing exists.

A missing field is not evidence that the device lacks the feature or performs poorly. It means we do not currently have a sufficiently comparable, sourced value in the normalized record.

Source labels preserve provenance. Manufacturer specifications, ingredient lists and performance claims are not treated as independent clinical evidence; regulatory records and independent measurements are identified separately when available.

Dose and irradiance context

What the output number means over time

Fluence is a calculation, not a treatment recommendation. For continuous output, fluence in J/cm² equals irradiance in mW/cm² × seconds ÷ 1000. The calculation only remains meaningful at the measurement conditions used for the irradiance value.

No comparable independent average irradiance is normalized

This device may have a manufacturer-published irradiance claim, but Homeapotherapy does not calculate time-to-fluence from that number unless the current record contains a sufficiently defined independent area-average measurement. This avoids presenting unlike measurement methods as interchangeable.

What this calculation still cannot tell you

  • whether this is an effective dose for any condition;
  • how irradiance changes at a different distance or across curved anatomy;
  • how much energy reaches tissue below the surface;
  • whether a study used the same wavelength distribution, spot size, pulse mode or treatment schedule;
  • whether peak irradiance would produce the same area exposure as the average value shown here.

Read Red Light Irradiance, Fluence and Dose Explained before trying to compare this output with a clinical paper or another panel.

Clinical evidence context

Where these wavelengths overlap with human research

Published device wavelengths: 630 / 660 / 810 / 850 nm.

This is a hardware-to-literature cross-reference, not a claim that this product treats any condition. A matching nominal wavelength does not reproduce a study's irradiance, dose, distance, treatment area, emitter geometry, schedule or patient population.

Research areas worth checking

Do not infer from wavelength overlap

  • that this device is clinically proven for the linked condition;
  • that more wavelengths are better;
  • that the highest published irradiance is the best dose;
  • that an open wound should be treated with a consumer device without appropriate wound assessment.

For wounds specifically, start with the wound-care safety decision guide before interpreting any device specification.

Safety first

What should make you slow down?

Use the current ULTRA-series manual for eye protection, electrical operation and pulse settings. Hardware controls are not efficacy claims.

  • The manual contains eye-exposure and electrical-safety warnings.
  • Manufacturer coverage and irradiance charts remain manufacturer evidence unless independently reproduced.

Where to buy

Current tracked merchants

Commerce note: merchant economics never enter our editorial score. Affiliate links are identified as (paid link) and use sponsored-link markup.

No merchant destination is currently tracked for this product.

Source trail

Primary documents and supporting evidence

  1. Hooga ULTRA Series User ManualHooga · Manufacturer manual · PDF · retrieved 2026-08-11
  2. Hooga Quality & Certifications: What We Can VerifyHooga · Manufacturer · retrieved 2026-08-10
  3. Photobiomodulation (PBM) Devices - Premarket Notification [510(k)] SubmissionsU.S. Food and Drug Administration · Regulatory · retrieved 2026-08-10