Homeapotherapy research desk Find my starting point

Product fact sheet

Vollara Air & Surface Pro+

Source-checked Vollara Air & Surface Pro+ specifications with explicit treatment of its purification plate, Depart Room Mode and ozone safety constraints.

Vollara and competitor evidence guideCompare filtration, airflow/CADR basis, coverage claims, ozone or ionization disclosures, power, sound and warranty without treating unlike room-size metrics as equivalent. Compare in context → Side-by-side air purifier comparisonOpen the comparison surface for this product family; missing comparable data is shown rather than guessed. Compare products →
Desk researchedFacts checked 2026-09-17

The Pro+ adds a purification plate and a high-ozone Depart Room Mode to a PCO-A/filtration platform; Vollara's manual restricts that mode to unoccupied spaces.

Fit signals

See documented specifications and comparison context.

Potential constraints

See technical gaps, safety notes and source limitations.

Key tradeoff: This model requires unusually careful mode-specific safety reading: its manual says it does not meet California requirements, cannot be shipped to California or Canada, and the Depart Room Mode is for unoccupied areas only.

This is a factual fit-and-tradeoff summary, not a product recommendation. Formula, device and brand claims remain manufacturer claims unless the cited source is explicitly regulatory or independent testing.

What makes the Pro+ materially different

The Pro+ is not simply the standard Pro with a larger specification. Its current manual describes a PCO-A cell, activated-carbon filter, HEPA filter screen and a purification plate. It lists 40–60 CFM airflow, 43 W maximum input, 45–55 dBA sound, a 7.6 lb weight and an enclosure measuring 11.8 × 9.5 × 10 inches.

The manual also describes a Depart Room Mode with purification-plate ozone output above 2.0 ppm and instructs that this mode be used only in an unoccupied area with no people or pets present. The same manual says the model does not meet California requirements and cannot be shipped to California or Canada.

Ozone safety context

EPA guidance on ozone-generating air cleaners says an EPA establishment number is not an endorsement and warns against ozone-generator use in occupied spaces. That is general public-health context; it is not an independent test of this Vollara unit.

Evidence boundary

Homeapotherapy has not measured ozone, particle removal or surface treatment for the Pro+. The product record preserves the manufacturer’s exact mode-specific safety wording rather than generalizing it to every operating mode.

Published specifications

Hardware facts and comparison fields

Air-treatment mechanism
PCO-A cell + activated carbon + HEPA screen + purification plate
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Filtration
Activated-carbon filter + HEPA filter screen
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Airflow / CADR basis
40–60 CFM fan airflow; no AHAM CADR in cited manual
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Published coverage
Up to 2,000 sq ft, subject to manufacturer conditions
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Maximum power
43 W
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Dimensions
11.8 × 9.5 × 10 in
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Weight
7.6 lb
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Sound
45–55 dBA
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)
Ozone / safety status
Depart Room Mode purification plate >2.0 ppm ozone; manual says use only with no people or pets present
Basis: Manufacturer manual The manual also says the unit does not meet California requirements and cannot be shipped to California or Canada. Source: Air & Surface Pro+ — Owner's Manual (PDF)
Warranty
3 years
Basis: Manufacturer manual Source: Air & Surface Pro+ — Owner's Manual (PDF)

What the current record does not establish

  • No Homeapotherapy common-protocol ozone or particulate measurement exists.
  • EPA guidance on ozone generators provides general safety context; it is not product-specific testing.

Source labels preserve provenance. Manufacturer specifications, ingredient lists and performance claims are not treated as independent clinical evidence; regulatory records and independent measurements are identified separately when available.

Safety first

What should make you slow down?

The Vollara manual restricts Depart Room Mode to unoccupied areas with no people or pets present and says this model does not meet California requirements; EPA guidance provides general ozone-generator safety context.

Where to buy

Current tracked merchants

Commerce note: merchant economics never enter our editorial score. Affiliate links are identified as (paid link) and use sponsored-link markup.

No merchant destination is currently tracked for this product.

Source trail

Primary documents and supporting evidence

  1. Air & Surface Pro+ — Owner's ManualVollara · Manufacturer manual · PDF · retrieved 2026-09-17
  2. Ozone Generators that are Sold as Air CleanersU.S. Environmental Protection Agency · Government health · retrieved 2026-09-17